1 / 5 page 0 4 000 - 10 000h at 105°C · Miniaturized · Low Impedance, High Current · Switching Power Supply Item Characteristics Operating Temperature Range (°C) -55 ~ +105 Voltage Range (V) 6,3 ~ 63 Capacitance Range (µF) 12 ~ 18 000 Capacitance Tolerance (20°C, 120Hz) ± 20% Leakage Current (µA) After 2 minutes at 20°C application of rated voltage, leakage current is not more than 0,01CV or 3, whichever is greater. C: Nominal Capacitance (µF) V: Rated Voltage (V) Dissipation Factor (20°C, 120Hz) Rated Voltage (V) 6, 10 16 2 0 6 Tan δ(max) 0,22 0,19 0,16 0,14 0,12 0,10 0,08 For Capacitances >1 000µF add 0,02 to every 1 000µF Stability at Low Temperature (Impedance Ratio at 120Hz) Rated Voltage (V) 6,3 ~ 63 Z -55°C / Z +20°C 3 CD 28L QL Series Useful Life Load Life Endurance Test Shelf Life Lifetime Ø ≤ 6,3 Ø 8 ~10 Ø ≥ 12 : 000h : 6 000h : 10 000h Ø ≥ 8: > 250 000h Ø ≤ 6,3 Ø 8 ~10 Ø ≥ 12 : 2 000h : 3 000h : 5 000h Ø ≤ 6,3 Ø 8 ~10 Ø ≥ 12 : 3 000h : 5 000h : 7 000h 1 000h Leakage Current Not more than specified value Not more than specified value Not more than specified value Not more than specified value Capacity Change Within ± 30% of initial value Within ± 20% of initial value Within ± 20% of initial value Within ± 20% of initial value Dissipation Factor Not more than 300% of specified value Not more than 200% of specified value Not more than 200% of specified value Not more than 200% of specified value Condition: Applied Voltage Applied Current Applied Temperature Failure Rate Level U R I R 105°C ≤ 1% Failure Rate U R 1,4 x I R 40°C ≤ 1% Failure Rate U R I R 105°C guaranteed U R I R = 0 105°C U R = 0 I R = 0 105°C After test: U R to be applied for 30min >24h before measurement Frequency Capacitance (µF) 120Hz 1kHz 10kHz 100kHz 12 ~ 180 0,40 0,75 0,90 1,00 220 ~ 560 0,50 0,83 0,93 1,00 680 ~ 1 800 0,60 0,86 0,95 1,00 2 200 ~ 3 900 0,75 0,90 0,97 1,00 4 700 ~ 18 000 0,85 0,95 0,98 1,00 Multiplier for Ripple Current Frequency Coefficient I A = actual ripple current at 100kHz, IR = rated ripple current at 100kHz, 105°C Multiplier of Useful Life as a function of ambient temperature and ripple current load Lifetime Diagram 40 50 60 70 80 90 100 110 CD 28L QL Series TA (˚C) IA ––– IR 2.5 2.0 1.5 1.0 0.5 0.0 X32 X16 X8 X4 X2 X1 Lifetime Multiplier CD 269 PH CD 284 XY CD 287 GC 125°C CD 281 LL lower ESR longest life CD 110 PT CD 28L QL lowest ESR 85°C smaller Direct Contact & Support: Jianghai Europe GmbH +49 (0)2151-652088-0 info@jianghai-europe.com www.jianghai-europe.com v2006.2 |
同様の部品番号 - CD28LQL |
|
同様の説明 - CD28LQL |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |