データシートサーチシステム |
|
6VM1SC データシート(PDF) 3 Page - Tyco Electronics |
|
6VM1SC データシート(HTML) 3 Page - Tyco Electronics |
3 / 8 page 126 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject Germany: 49-89-6089-0 are metric equivalents. to change. CORCOM Product Guide M Series Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued) Electrical Schematics – Unfiltered Models VM (1-Voltage) K L G G Neutral Hot Power On/Off Note 3 Note 2 Customer Transformer Primaries L K 120V VM (2-Voltage) B D E F A C D E F HB J G Neutral Hot Power On/Off Note 3 Note 2 Note 1 Note 1 Note 4 120V 240V Customer Transformer Primaries L L K K C F A 120V 120V 120V 120V VM (4-Voltage) A C D E F A C D E F H B J G Neutral Hot Power On/Off Note 3 Note 2 Note 1 Note 1 120V 100V 230V 240V Customer Transformer Primaries L K 20V 100V 120V Note 1: Jumpers required if no input filter is used. Note 2: Provision for dual European style fusing. Note 3: On/off switch present only with "S" suffix. Note 4: When using a center-tapped transformer, the C-F winding should be the low voltage (high current) winding and must be capable of handling the full primary current in the 120V position. Specifications Maximum leakage current,each line-to-ground HM FM XM/ZM @ 120 VAC 60 Hz: 2 µA .25 mA .30 mA @ 250 VAC 50 Hz: 5 µA .50 mA .50 mA Hipot rating (one minute): line-to-ground: 1500 VAC line-to-line 1450 VDC line-to-load (switch off) Unfiltered only 2500 VAC Operating frequency: 50/60 Hz Rated voltage (max.): 250 VAC Operating voltages: 100, 120, 220/ 240 VAC Switch: Double-insulated, rated for 100,000 operations at full load at 70 Amps inrush current. Fuse (not included): Reversible fuseholder, accepts one 1/4" x 1-1/4" fuse or two 5 x 20 mm fuses Terminals: .110 [2.79] terminals Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Frequency-MHz Rating .01 .05 .15 .5 1 5 10 30 HM 5A - - 14 18 19 22 22 17 FM 05A - - 14 21 26 40 45 40 XM 3A 2 13 23 40 46 44 44 44 ZM 3A 15 29 39 46 43 40 40 40 Line-to-line in 50 ohm circuit Current Frequency-MHz Rating .02 .03 .05 .07 .15 .5 1 5 10 30 XM 03A - - - 5 34 62 68 60 50 40 ZM 3A 5 13 28 37 55 75 75 62 54 44 |
同様の部品番号 - 6VM1SC |
|
同様の説明 - 6VM1SC |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |