データシートサーチシステム |
|
3VR7 データシート(PDF) 1 Page - Tyco Electronics |
|
3VR7 データシート(HTML) 1 Page - Tyco Electronics |
1 / 2 page Two-Stage General Purpose RFI Power Line Filter The dual T section RFI power line filters provide premium performance at moderate cost. They are well suited for low impedance loads where noisy RFI environments are present. They control pulsed, continuous and/or intermittent interference, providing protection to your equipment from power line noise in addition to protecting the line from equipment noise. The R series dual T type provides low leakage current without deterioration of insertion loss characteristics and at a competitive cost. The ER models meet the low leakage current requirements of VDE portable equipment, and (120 Volt) UL2601 non-patient medical equipment. Specifications Maximum leakage current,each line-to-ground VR Models ER Models @ 120 VAC 60 Hz: .4 mA .21 mA @ 250 VAC 50 Hz: .7 mA .36 mA Hipot rating (one minute): line-to-ground 2250 VDC line-to-line 1450 VDC Operating frequency: 50/60 Hz Rated voltage (max.): 250 VAC Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Frequency–MHz Rating .15 .5 1 5 10 30 VR Models 1A, 3A 30 65 65 65 65 65 2A, 5A, 10A, 20A 5 44 60 65 65 60 ER Models 1A, 3A 25 60 65 65 65 65 2A, 5A, 10A, 20A 2 35 51 63 60 50 Line-to-line in 50 ohm circuit Current Frequency–MHz Rating .15 .5 1 5 10 30 VR, ER Models 1A, 3A – – 65 60 54 46 2A, 5A, 10A, 20A – – 35 60 57 45 84 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com specified. Values in italics Specifications subject Germany: 49-89-6089-0 are metric equivalents. to change. R Series R Series CORCOM Product Guide Electrical Schematic Resistor location for reference only. LINE LOAD 10VR6 VR7/ER7 VR1/ER1 VR3/ER3 Case Style 20VR6 Note: Same layout for 20VR1 and 20ER1, except .250 [6.35] (5) terminals replace Screw Terminals of 20VR6. E DB 2.00 50.8 A Terminals: No. 8-32 (5) C Slots: .250 6.35 .156 3.96 x (4) Torque 18 ± 2 in.lb UL Recognized CSA Certified VDE Approved |
同様の部品番号 - 3VR7 |
|
同様の説明 - 3VR7 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |