  U1230 Datasheet HTML 1Page - Agilent(Hewlett-Packard) U1230 Datasheet HTML 2Page - Agilent(Hewlett-Packard) U1230 Datasheet HTML 3Page - Agilent(Hewlett-Packard) U1230 Datasheet HTML 4Page - Agilent(Hewlett-Packard) U1230 Datasheet HTML 5Page - Agilent(Hewlett-Packard) U1230 Datasheet HTML 6Page - Agilent(Hewlett-Packard) U1230 Datasheet HTML 7Page - Agilent(Hewlett-Packard) U1230 Datasheet HTML 8Page - Agilent(Hewlett-Packard) U1230 Datasheet HTML 9Page - Agilent(Hewlett-Packard) Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 10 page
background image
5
Electrical Specifications
Temperature specifications
Thermal type
Range
Resolution
Accuracy± (% of reading +
counts of least significant digit)
U1233A
K
–40 °C to 1372 °C
0.1 °C
1% + 1 °C
–40 °F to 2502 °F
0.1 °F
1% + 1.8 °F
Notes:
1. The specification above is specified after 60 minutes of warm up time. If the unit is exposed during storage in high humidity (condensing)
environment, 120 minutes of operating time is required instead.
2. The accuracy does not include the tolerance of the thermocouple probe.
3. Do not allow the temperature sensor to contact a surface that is energized above 30 Vrms or 60 V DC. Such voltages poses a shock hazard.
4. Ensure that the ambient temperature is stable within ±1 ºC and that the Null function is used to reduce the test lead’s thermal effect and temperature
offset. Before using Null function, set the multimeter to measure temperature without ambient compensation (°C) and keep the thermocouple probe
as close as possible to the multimeter (avoid contact with any surface that has a different temperature from the ambient temperature).
5. When measuring temperature with respect to any temperature calibrator, try to set both the calibrator and multimeter with an external reference
(without internal ambient compensation). If both the calibrator and multimeter are set with internal reference (with internal ambient compensation),
some deviations may show between the readings of the calibrator and multimeter, This difference is caused from the calibrator and multimeters’s
ambient compensation. The deviation can be reduced by keeping the multimeter close to the output terminal of calibrator.
6. The temperature calculation is specified according to the safety standards of EN/IEC-60548-1and NIST175.
7. The approximate ambient temperature (cold-junction compensation) is shown on the display when you have an open thermocouple. The open
thermocouple message may be due to broken (open) probe or because no probe is installed into the input jacks of the multimeter.
Frequency specifications
Range
Resolution
Accuracy± (% of reading +
counts of least significant digit)
Minimum input frequency
U1231A/U1232A/U1233A
99.99 Hz
0.01 Hz
0.1% + 2
5 Hz
999.9 Hz
0.1 Hz
0.1% + 2
9.999 kHz
1 Hz
0.1% + 2
99.99 kHz
10 Hz
0.1% + 2
Notes:
1. Overload protection: 600 V; input signal is < 20,000,000 V × Hz (product of voltage and frequency).


同様の部品番号 - U1230

メーカー部品番号データシート部品情報
logo
Keysight Technologies
U1230 KEYSIGHT-U1230 Datasheet
2Mb / 13P
   Digital Multimeters (DMMs)
More results

同様の説明 - U1230

メーカー部品番号データシート部品情報
logo
Agilent(Hewlett-Packard...
U1241A HP-U1241A Datasheet
371Kb / 6P
   U1241A/U1242A Handheld Digital Multimeter
logo
Extech Instruments Corp...
MS400 EXTECH-MS400 Datasheet
841Kb / 51P
   Handheld Digital Storage Oscilloscope & Multimeter
DM100 EXTECH-DM100 Datasheet
159Kb / 2P
   Pocket Multimeter 4000 Count Autoranging DMM
DM110 EXTECH-DM110 Datasheet
148Kb / 2P
   Pocket Multimeter 4000 Count Autoranging DMM
logo
TEKTRONIX, INC.
DMM4040 TEKTRONIX-DMM4040 Datasheet
2Mb / 112P
   Digital Multimeter
DMM7510 TEKTRONIX-DMM7510 Datasheet
1Mb / 27P
   DMM 7510 7쩍-Digit Graphical Sampling Multimeter
logo
List of Unclassifed Man...
D35 ETC-D35 Datasheet
215Kb / 2P
   Bluetooth Digital Multimeter
logo
Keysight Technologies
34450A KEYSIGHT-34450A Datasheet
2Mb / 12P
   34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM
34401A KEYSIGHT-34401A Datasheet
863Kb / 6P
   34401A Digital Multimeter
logo
Extech Instruments Corp...
MN15A EXTECH-MN15A Datasheet
321Kb / 12P
   Mini Digital Multimeter
More results


Html Pages

1 2 3 4 5 6 7 8 9 10


データシート ダウンロード

Go To PDF Page


リンク URL




プライバシーポリシー
ALLDATASHEET.JP
ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com