3 / 9 page 2 Electrical Specifications DC specifications Function Range Resolution Test current/ burden voltage Accuracy ± (% of reading + counts of least significant digit) U1241B U1242B Voltage1 1000.0 mV 0.1 mV – 0.09% + 5 10.000 V 0.001 V – 0.09% + 2 100.00 V 0.01 V – 1000.0 V 0.1 V – 0.15% + 5 Current 1000.0 µA 0.1 µA < 0.06 V (50 Ω) 0.1% + 3 10000 µA 1 µA < 0.55 V (50 Ω) 0.1% + 3 100.00 mA 0.01 mA < 0.18 V (0.5 Ω) 0.2% + 3 440.0 mA2 0.1 mA < 0.8 V (0.5 Ω) 0.5% + 3 10.000 A3 0.001 A < 0.4 V (0.01 Ω) 0.6% + 5 Resistance4 1000.0 Ω5 0.1 Ω 0.5 mA 0.3% + 3 10.000 kΩ5 0.001 kΩ 50 µA 100.00 kΩ 0.01 kΩ 4.91 µA 1000.0 kΩ 0.1 kΩ 447 nA 10.000 MΩ 0.001 MΩ 112 nA 0.8% + 3 100.00 MΩ6 0.01 MΩ 112 nA 1.5% + 3 Diode test7 1 V 0.001 V approximately 0.5 mA 0.3% + 2 1. Input impedance: 10 MΩ (nominal). 2. Current can be measured up to 440 mA continuously. An additional 0.2% needs to be added to the specified accuracy if the signal measured is in the range of 440 mA to 1100 mA for 30 seconds maximum. After measuring a current of > 440 mA, leave the meter to cool down for twice the measur- ing time used before applying a low current measurement. 3. Current can be measured up to 10 A continuously with a maximum operating temperature of 50 °C. An additional 0.3% needs to be added to the specified accuracy if the signal measured is in the range of 10 A to 19.999 A for 15 seconds maximum. After measuring a current of > 10 A, leave the meter to cool down for 60 seconds before applying a low current measurement. 4. The maximum open voltage is < 2.8 V. For instant continuity, the built-in buzzer sounds when resistance is < 10.0 Ω. 5. The accuracy of 1 kΩ and 10 kΩ is specified after Null function, which is used to substrate the test lead resistance and the thermal effect. 6. For the range of 100 MΩ, the R.H. is specified for < 60%. The temperature coefficient will be 0.15 times of specified accuracy as > 50 MΩ. 7. Overload protection: 1000 V RMS for circuits < 0.3 A short circuit current. The built-in buzzer sounds when reading is approximately below 50 mV and audible single tone for normal forward biased diode or semiconductor junction as 0.3 V ≤ Reading ≤ 0.8 V. |
同様の部品番号 - U1180A |
|
同様の説明 - U1180A |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |