10 / 14 page Typical Applications (Continued) Centigrade Calibrated Thermocouple Thermometer DS005698-12 Terminate thermocouple reference junction in close proximity to LM335. Adjustments: 1. Apply signal in place of thermocouple and adjust R3 for a gain of 245.7. 2. Short non-inverting input of LM308A and output of LM329B to ground. 3. Adjust R1 so that VOUT = 2.982V @ 25˚C. 4. Remove short across LM329B and adjust R2 so that VOUT = 246 mV @ 25˚C. 5. Remove short across thermocouple. Fast Charger for Nickel-Cadmium Batteries DS005698-13 †Adjust D1 to 50 mV greater VZ than D2. Charge terminates on 5˚C temperature rise. Couple D2 to battery. Differential Temperature Sensor DS005698-7 www.national.com 10 |
同様の部品番号 - LM135 |
|
同様の説明 - LM135 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |