データシートサーチシステム |
|
AD7147 データシート(PDF) 31 Page - Analog Devices |
|
AD7147 データシート(HTML) 31 Page - Analog Devices |
31 / 71 page AD7147 Data Sheet Rev. E | Page 30 of 70 STAGE0 STAGE1 STAGE2 STAGE3 STAGE4 STAGE5 STAGE6 STAGE7 STAGE8 STAGE9 STAGE10 STAGE11 23 1 INT CONVERSIONS SERIAL READS NOTES THIS IS AN EXAMPLE OF A CDC CONVERSION-COMPLETE INTERRUPT. THIS TIMING EXAMPLE SHOWS THAT THE INTERRUPT OUTPUT HAS BEEN ENABLED TO BE ASSERTED AT THE END OF A CONVERSION CYCLE FOR STAGE0, STAGE5, AND STAGE9. THE INTERRUPTS FOR ALL OTHER STAGES HAVE BEEN DISABLED. STAGEx CONFIGURATION PROGRAMMING NOTES FOR STAGE0, STAGE5, AND STAGE9 (x = 0, 5, 9): STAGEx_LOW_INT_ENABLE (ADDRESS 0x005) = 0 STAGEx_HIGH_INT_ENABLE (ADDRESS 0x006) = 0 STAGEx_COMPLETE_INT_ENABLE (ADDRESS 0x007) = 1 STAGEx CONFIGURATION PROGRAMMING NOTES FOR STAGE1 THROUGH STAGE8, STAGE10, AND STAGE11 (x = 1, 2, 3, 4, 5, 6, 7, 8, 10, 11): STAGEx_LOW_INT_ENABLE (ADDRESS 0x005) = 0 STAGEx_HIGH_INT_ENABLE (ADDRESS 0x006) = 0 STAGEx_COMPLETE_INT_ENABLE (ADDRESS 0x007) = 0 SERIAL READBACK REQUIREMENTS FOR STAGE0, STAGE5, AND STAGE9 (THIS READBACK OPERATION IS REQUIRED TO CLEAR THE INTERRUPT OUTPUT.): 1READ THE STAGE0_COMPLETE_INT_STATUS (ADDRESS 0x00A) BIT 2READ THE STAGE5_COMPLETE_INT_STATUS (ADDRESS 0x00A) BIT 3READ THE STAGE9_COMPLETE_INT_STATUS (ADDRESS 0x00A) BIT Figure 41. Example of Configuring the Registers for Conversion-Complete Interrupt Setup 42 1 INT CONVERSIONS SERIAL READS NOTES THIS IS AN EXAMPLE OF A SENSOR-TOUCH INTERRUPT FOR A CASE WHERE THE LOW THRESHOLD LEVELS WERE EXCEEDED. FOR EXAMPLE, THE SENSOR CONNECTED TO STAGE0 AND STAGE9 WERE CONTACTED, AND THE LOW THRESHOLD LEVELS WERE EXCEEDED, RESULTING IN THE INTERRUPT BEING ASSERTED. THE STAGE6 INTERRUPT WAS NOT ASSERTED BECAUSE THE USER DID NOT CONTACT THE SENSOR CONNECTED TO STAGE6. STAGEx CONFIGURATION PROGRAMMING NOTES FOR STAGE0, STAGE6, AND STAGE9 (x = 0, 6, 9): STAGEx_LOW_INT_ENABLE (ADDRESS 0x005) = 1 STAGEx_HIGH_INT_ENABLE (ADDRESS 0x006) = 0 STAGEx_COMPLETE_INT_ENABLE (ADDRESS 0x007) = 0 STAGEx CONFIGURATION PROGRAMMING NOTES FOR STAGE1 THROUGH STAGE7, STAGE8, STAGE10, AND STAGE11 (x = 1, 2, 3, 4, 5, 6, 7, 8, 10, 11): STAGEx_LOW_INT_ENABLE (ADDRESS 0x005) = 0 STAGEx_HIGH_INT_ENABLE (ADDRESS 0x006) = 0 STAGEx_COMPLETE_INT_ENABLE (ADDRESS 0x007) = 0 SERIAL READBACK REQUIREMENTS FOR STAGE0 AND STAGE9 (THIS READBACK OPERATION IS REQUIRED TO CLEAR THE INTERRUPT OUTPUT.): 1READ THE STAGE0_LOW_INT_STATUS (ADDRESS 0x008) BIT 2READ THE STAGE5_LOW_INT_STATUS (ADDRESS 0x008) BIT STAGE0 STAGE1 STAGE2 STAGE3 STAGE4 STAGE5 STAGE6 STAGE7 STAGE8 STAGE9 STAGE10 STAGE11 Figure 42. Example of Configuring the Registers for Sensor-Touch Interrupt Setup |
同様の部品番号 - AD7147_17 |
|
同様の説明 - AD7147_17 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |