6 / 7 page TS2026L 6-7 2005/11 rev. A Function Description Fault Flag The FLG signal is an N-channel open-drain MOSFET output. FLG is asserted (active-low) when either an over current or thermal shutdown condition occurs. In the case of and over current condition, FLG will be asserted only after the flag response delay time, tD, has elapsed. This ensured that FLG is asserted only upon valid over current conditions and that erroneous error reporting is eliminated. For example, false over current condition can occur during hot plug event when a highly capacitive load is connected and causes a high transient inrush current that exceeds the current-limit threshold for up to 1ms. The FLG response delay time tD is typically 3ms. Undervoltage Lockout Undervoltage lockout (UVLO) prevents the output MOSFET from turning on until VIN exceeds approximately 2.5V. Undervoltage detection function only when the switch is enabled. Figure 1. TS2026L Fault Timing |
同様の部品番号 - TS2026L |
|
同様の説明 - TS2026L |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |