データシートサーチシステム |
|
LM124AWG データシート(PDF) 11 Page - National Semiconductor (TI) |
|
|
LM124AWG データシート(HTML) 11 Page - National Semiconductor (TI) |
11 / 27 page LM124A RAD HARD — DC Drift Values (Note 10) (The following conditions apply to all the following parameters, unless otherwise specified.) DC: "Delta calculationsperformed on QMLV devices at group B, subgroup 5 only" SYMBOL PARAMETER CONDITIONS NOTES MIN MAX UNIT SUB- GROUPS Vio Input Offset Voltage Vcc+ = 30V, Vcc- = Gnd, Vcm = -15V -0.5 0.5 mV 1 ±Iib Input Bias Current Vcc+ = 30V, Vcc- = Gnd, Vcm = -15V -10 10 nA 1 Electrical Characteristics — POST RADIATION LIMITS +25˚C (Note 10) (The following conditions apply to all the following parameters, unless otherwise specified.) All voltages referenced to device ground. SYMBOL PARAMETER CONDITIONS NOTES MIN MAX UNIT SUB- GROUPS Vio Input Offset Voltage Vcc+ = 30V, Vcc- = Gnd, Vcm = -15V (Note 10) -2.5 2.5 mV 1 Vcc+ = 2V, Vcc- = -28V, Vcm = 13V (Note 10) -2.5 2.5 mV 1 Vcc+ = 5V, Vcc- = GND, Vcm = -1.4V (Note 10) -2.5 2.5 mV 1 Vcc+ = 2.5V, Vcc- = -2.5, Vcm = 1.1V (Note 10) -2.5 2.5 mV 1 Iio Input Offset Current Vcc+ = 30V, Vcc- = GND, Vcm = -15V (Note 10) -15 15 nA 1 Vcc+ = 2V, Vcc- = -28V, Vcm = 13V (Note 10) -15 15 nA 1 Vcc+ = 5V, Vcc- = GND, Vcm = -1.4V (Note 10) -15 15 nA 1 Vcc+ = 2.5V, Vcc- = -2.5V, Vcm = 1.1V (Note 10) -15 15 nA 1 ±Iib Input Bias Current Vcc+ = 30V, Vcc- = GND, Vcm = -15V (Note 10) -75 +0.1 nA 1 Vcc+ = 2V, Vcc- = -28V, Vcm = 13V (Note 10) -75 +0.1 nA 1 Vcc+ = 5V, Vcc- = GND, Vcm = -1.4V (Note 10) -75 +0.1 nA 1 Vcc+ = 2.5V, Vcc- = -2.5V, Vcm = 1.1V (Note 10) -75 +0.1 nA 1 Avs+ Voltage Gain Vcc+ = 30V, Vcc- = GND, 1V ≤ Vo ≤ 26V, Rl = 10K Ohms (Note 10) 40 V/mV 4 Vcc+ = 30V, Vcc- = GND, 5V ≤ Vo ≤ 20V, Rl = 2K Ohms (Note 10) 40 V/mV 4 Note 6: Guaranteed by Vio tests. Note 7: Datalog reading in K=V/mV Note 8: Guaranteed, not tested Note 9: Calculated parameters Note 10: Pre and post irradiation limits are identical to those listed under AC and DC electrical characteristics except as listed in the Post Radiation Limits Table. These parts may be dose rate sensitive in a space environment and demonstrate enhanced low dose rate effect. Radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, Method 1019 www.national.com 11 |
同様の部品番号 - LM124AWG |
|
同様の説明 - LM124AWG |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |