9 / 12 page 3940 FULL-BRIDGE POWER MOSFET CONTROLLER www.allegromicro.com 9 Functional Description Motor Lead Protection. A fault detection circuit monitors the voltage across the drain to source of the external MOSFETs. A fault is asserted “high” on the output terminal, FAULT, if the drain-to-source voltage of any MOSFET that is instructed to turn on is greater than the voltage applied to the V DSTH input terminal. When a high-side switch is turned on, the voltage from V DRAIN to the appropriate motor phase output, V SX, is examined. If the motor lead is shorted to ground the measured voltage will exceed the threshold and the FAULT terminal will go “high”. Similarly, when a low-side MOSFET is turned on, the differen- tial voltage between the motor phase (drain) and the LSS terminal (source) is monitored. V DSTH is set by a resistor divider to V REG5. To prevent erroneous motor faults during switching, the fault circuitry will wait two dead times after every PWM/phase change before monitoring the drain-to-source voltage; except, it will use one dead time for (1) a long coast to any phase on, or (2) a long hi-Z before on for that phase. This allows time for the motor output voltage to settle before checking for motor fault when using slow rise/fall gate-control waveforms. The V DRAIN is intended to be a Kelvin connection for the high-side, drain-source monitor circuit. Voltage drops across the power bus are eliminated by connecting an isolated PCB trace from the V DRAIN terminal to the drain of the MOSFET bridge. This allows improved accuracy in setting the V DSTH threshold voltage. The low-side, drain-source monitor uses the LSS terminal, rather than V DRAIN, in comparing against VDSTH. Fault States. The FAULT terminal provides real time indication of fault conditions after some digital noise filtering. The V DRAIN fault acts as if a short-to-ground fault existed on every motor phase. Bridge (or motor) faults are latched but cleared by a RESET = 0 pulse or by power cycling. GHx = GLx = 0 during RESET = 0. The undervoltage, overvoltage, and thermal shutdown faults are not latched and will not reset until the cause is eliminated. All faults cause, via the FAULT line, a coast and some cause shutdown of the regulators, as in the Fault Responses table (next page). Note: As a test mode, if the thermal shutdown or SLEEP has not occurred and the FAULT output is externally held low, the coast mode and regulator shutdowns will not occur if motor or voltage faults occur. Do not wire-OR this terminal to other FAULT lines. Dead Time. The A3940 is intended to drive a wide range of power MOSFETs in applications requiring a wide range of switching times. In order to prevent cross conduction (a.k.a. shoot-through) during direction and PWM changes, a power MOSFET must be turned off before its “phase-pin mate” is turned on. tDEAD(ns) = K([18.8RDEAD(k Ω)] + 50) + 90 where K = 1 for LONG = 0; K = 32 for LONG = 1. Note: IDEAD(mA) ≈ 2/R DEAD(k Ω), 12 kΩ<R DEAD<500 kΩ. Sleep Mode. RESET = 0 clears any latched motor faults while driving all gate drive outputs low (coast). Eventually, RESET = 0 turns off all circuits to allow minimum current draw. GHx and GLx outputs go high impedance (Z) when VREG13 < 4 V. RESET = 1 enables the device after it powers up all circuits. The user should wait the pump-up time, t up, to allow the device to be powered up properly before a gate output is enabled. Please refer to power-up diagram in application note AN295040 for more detail. Charge Pump. The A3940 is designed to accommodate a wide range of power supply voltages. The charge pump output voltage, VCP, is regulated to VBB + 11 V (or about 2VBB if VBB < 11 V). VREG13. A 13.3 V, low-dropout, linear regulator is used to power the low-side gate drive circuit directly and to provide the current to charge the bootstrap capacitors for the high-side gate drive. The input supply connection to this regulator, VIN, can be externally connected to the charge pump output, VCP, or it can be directly connected to the VBB or VBAT terminal. Internal current limiting protects VREG13. VREG5. A 5 V, low-dropout, linear regulator is used to power the internal logic, regulators, and thermal detection. This regulator can also power low-current external resistor networks for VDSTH and OVSET, and the FAULT output pull-up. The input supply connection is VBB. Internal current limiting protects VREG5. Power-Up State. If the input logic is open, internal pull- downs put the system in coast mode on powering up. First, issue a brake command for >10 µs to charge the bootstrap capacitors and avoid a possible short-to-ground fault indication. |
同様の部品番号 - 3940_03 |
|
同様の説明 - 3940_03 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |