データシートサーチシステム |
|
ST-3 データシート(PDF) 2 Page - Systemsensor advanced ideas. |
|
ST-3 データシート(HTML) 2 Page - Systemsensor advanced ideas. |
2 / 4 page The duct smoke detector shall be a System Sensor Model ED-DPR Intelligent Duct Smoke Detector to be used with com- patible control panels. The duct smoke detector shall be UL listed per UL 268A, Standard for Smoke Detectors for Duct Applications, specifically for use in air handling systems. The detector shall oper- ate in air velocities from 500 to 4000 feet per minute. The detector housing shall be equipped with an integral mounting base capable of accommodating either the ED- DP or ED-DPI photoelectric detector head. It shall be capable of remote testing from the RTS451 or RTS451KEY Remote Test Station. The duct smoke detector housing shall incorporate an airtight smoke cham- ber in compliance with UL 268A. The housing shall be capable of mounting to either rectangular or round ducts without adapter brackets. An integral filter system shall be included to reduce dust and resi- due effects, thereby reducing maintenance and servicing. Sampling tubes shall be eas- ily installed after the housing is mounted to the duct by passing through the duct housing. Terminal connections shall be of the strip and clamp method suitable for 14-18 AWG wiring. Architect/Engineer Specifications Wiring diagram for ED-DPR Duct Smoke Detector with optional RA400Z Wiring diagram for ED-DPR Duct Smoke Detector with RTS451/RTS451KEY - + OPTIONAL RETURN LOOP (–) COM LINE TO REST OF SYSTEM (+) COM LINE TO REST OF SYSTEM SLC SLC 2 1 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 1 2 3 1 2 3 GROUND RTS451/ 451KEY 5 4 1 2 DUCT DETECTOR RTS451/RTS451KEY REMOTE TEST STATION ALARM (LED) 5 8 7 4 TEST (+) TEST (+) TEST (–) TEST (–) (–) (+) 4 6 (+) (–) DUCT DETECTOR Break Tab on RA400Z for use with ED-DPR. RA400Z REMOTE ANNUNCIATOR RED Wiring diagram for ED-DPR Duct Smoke Detector using a UL listed control panel Note: For terminals 9 through 14, normally closed and normally opened relay positions are defined with product in reset condition, not in alarm. |
同様の部品番号 - ST-3 |
|
同様の説明 - ST-3 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |