データシートサーチシステム |
|
ST-10 データシート(PDF) 2 Page - Gamewell-FCI by Honeywell |
|
ST-10 データシート(HTML) 2 Page - Gamewell-FCI by Honeywell |
2 / 4 page SS-PD and SS-PDR CS-2463 10/21/04 Page 2 of 4 Specifications SS-PD Operating voltage range 15 to 32 VDC. Standby current 300 µA @ 24 VDC (one communi- cation every 5 seconds with LED blink enabled). Operating temperature range 32° to 131°F (0° to 55°C). Relative Humidity range 10% to 93% (non-condensing). Duct air velocity 100 to 4,000 feet/min (0.5 to 20.32 m/s). Dimensions 14.750" (37 cm) length x 5.500" (14 cm) width x 2.750" (7 cm) deep. Options 1. RTS-451, RTS-451KEY, RA400Z. 2. PA400 (Review installation instruc- tions on power requirements) . SS-PDR Operating voltage range 20 to 30 VDC, 24 VAC/VDC, 120/ 240 VAC auxiliary power (requires a separate auxiliary source). Standby current 300 µA @ 24 VDC (one communi- cation every 5 seconds with LED blink enabled). Operating temperature range 32° to 131°F (0° to 55°C). Relative Humidity range 10% to 93% (non-condensing). Duct air velocity 100 to 4,000 feet/min (0.5 to 20.32 m/s). Dimensions 14.750" (37 cm) length x 5.500" (14 cm) width x 2.750" (7 cm) deep. Options 1. RTS-451, RTS-451KEY, RA400Z. 2. PA400 (Review installation instruc- tions on power requirements). 10 Amp @ 30 VDC 10 Amp @ 277 VAC (0.75 Pow er Factor) 240 VAC @ 249 VAC (0.4 Pow er Factor) 1/8 HP @ 120 VAC 1/4 HP @ 240 VAC Supervisory Contact (SPST) 2.0 Amp @ 30 VDC (resistive) SS-PDR: Relay Contact Ratings Alarm Auxiliary Contacts * (DPDT) Minimum sw itching current of 100 mA @ 5 VDC. Pow e r Supply Voltage 30-30VDC 24VAC, 50/60 Hz 120VAC, 50/60 Hz 220/240 VAC, 50/60 Hz Max. Standby Current 26 Ma 65 mA RMS 44 mA RMS 25 mA RMS Max Alarm Current 87 mA 182 mA RMS 52 mA RMS 30 mA RMS Alarm Response Tim e 3 to 17 Sec. 3 to 17 Sec. 3 to 17 Sec. 3 to 17 Sec. Pow e r Up Tim e 2 Sec. 2 Sec. 2 Sec. 2 Sec. SS-PD: Current Requirem ents (us ing no access ories) The RA400Z The RTS451 The RTS451KEY Programming specifications requirements for intelligent system control panels: The number of devices that can have their LEDs programmed to illuminate is limited by the fea- tures of the panel and the indi- vidual devices. The actual num- ber of devices is determined by the control panel and its ability to supply LED cur- rent. Refer to the control panel installation manual for details. Product Line Information Model Description SS-PD Duct detector housing with SmartScan™ photoelectric smoke detector. SS-PDR Duct detector housing with SmartScan™ photoelectric smoke detector, DPDT relay. A5053GM Replacement photoelectric sensor board. A5067 Replacement power board (without relay). A5060 Replacement power board (with relay). ST-1.5 Metal sampling tube, duct widths 1' to 2' (see table at left for metric lengths). ST-3 Metal sampling tube, duct widths 2' to 4'. ST-5 Metal sampling tube, duct widths 4' to 8'. ST-10 Metal sampling tube, duct widths 8' to 12'. RA400Z Remote annunciator alarm LED. RTS451 Remote test station. Mounts in single-gang box. Includes red alarm LED and magnet test switch. RTS451KEY Key-activated remote test station. F36-09-11 Replacement filters. M02-04-00 Replacement test magnet. S08-39-01 Replacement photo insect screen. |
同様の部品番号 - ST-10 |
|
同様の説明 - ST-10 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |