データシートサーチシステム |
|
SN74LV4052ATPWREP データシート(PDF) 4 Page - Texas Instruments |
|
|
SN74LV4052ATPWREP データシート(HTML) 4 Page - Texas Instruments |
4 / 12 page SN74LV4052AEP DUAL 4CHANNEL ANALOG MULTIPLEXER/DEMULTIPLEXER SCLS502C − MAY 2003 − REVISED MAY 2004 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 switching characteristics over recommended operating free-air temperature range, VCC = 3.3 V ± 0.3 V (unless otherwise noted) PARAMETER FROM (INPUT) TO (OUTPUT) TEST CONDITIONS MIN MAX UNIT tPLH tPHL Propagation delay time COM or Y Y or COM CL = 50 pF, (see Figure 4) 12 ns tPZH tPZL Enable delay time INH COM or Y CL = 50 pF, (see Figure 5) 25 ns tPHZ tPLZ Disable delay time INH COM or Y CL = 50 pF, (see Figure 5) 25 ns switching characteristics over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V (unless otherwise noted) PARAMETER FROM (INPUT) TO (OUTPUT) TEST CONDITIONS MIN MAX UNIT tPLH tPHL Propagation delay time COM or Y Y or COM CL = 50 pF, (see Figure 4) 8 ns tPZH tPZL Enable delay time INH COM or Y CL = 50 pF, (see Figure 5) 18 ns tPHZ tPLZ Disable delay time INH COM or Y CL = 50 pF, (see Figure 5) 18 ns analog switch characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER FROM TO TEST VCC TA = 25°C UNIT PARAMETER FROM (INPUT) TO (OUTPUT) TEST CONDITIONS VCC MIN TYP MAX UNIT Frequency response CL = 50 pF, R = 600 , 2.3 V 30 Frequency response (switch on) COM or Y Y or COM CL = 50 pF, RL = 600 Ω, fin = 1 MHz (sine wave) 3 V 35 MHz (switch on) COM or Y Y or COM fin = 1 MHz (sine wave) (see Note 5 and Figure 6) 4.5 V 50 MHz Crosstalk CL = 50 pF, R = 600 , 2.3 V −45 Crosstalk (between any switches) COM or Y Y or COM CL = 50 pF, RL = 600 Ω, fin = 1 MHz (sine wave) 3 V −45 dB (between any switches) COM or Y Y or COM fin = 1 MHz (sine wave) (see Note 6 and Figure 7) 4.5 V −45 dB Crosstalk CL = 50 pF, R = 600 , 2.3 V 20 Crosstalk (control input to signal output) INH COM or Y CL = 50 pF, RL = 600 Ω, fin = 1 MHz (square wave) 3 V 35 mV (control input to signal output) INH COM or Y fin = 1 MHz (square wave) (see Figure 8) 4.5 V 65 mV Feedthrough attenuation CL = 50 pF, R = 600 , 2.3 V −45 Feedthrough attenuation (switch off) COM or Y Y or COM CL = 50 pF, RL = 600 Ω, fin = 1 MHz (sine wave) 3 V −45 dB (switch off) COM or Y Y or COM fin = 1 MHz (sine wave) (see Note 6 and Figure 9) 4.5 V −45 dB CL = 50 pF, RL = 10 kΩ, VI = 2 Vp-p 2.3 V 0.1 Sine-wave distortion COM or Y Y or COM RL = 10 kΩ, fin = 1 kHz (sine wave) VI = 2.5 Vp-p 3 V 0.1 % in (sine wave) (see Figure 10) VI = 4 Vp-p 4.5 V 0.1 NOTES: 5. Adjust fin voltage to obtain 0 dBm at output. Increase fin frequency until dB meter reads −3 dB. 6. Adjust fin voltage to obtain 0 dBm at input. |
同様の部品番号 - SN74LV4052ATPWREP |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |