データシートサーチシステム |
|
3--21028-2 データシート(PDF) 2 Page - Tyco Electronics |
|
3--21028-2 データシート(HTML) 2 Page - Tyco Electronics |
2 / 5 page 408- 6930 Rev F 2 of 5 2. Using a small knife, cut off the wire retainers (strain relief) of the connector. This will provide a clear view for inspecting the connector for a properly terminated wire in the contact. See Figure 3. Wire retainers are removed in a connector for testing only. DO NOT use such connectors for production application. 3. Make a test termination according to Steps 1 through 5 of Section 5, TERMINATING PROCEDURE. 4. Push the connector out of the right side of the head. 5. Check that the wire insertion depth is within the dimension given in Figure 3. To obtain the wire insertion depth, measure from the front of the contact beam to the center of the wire as shown in Figure 3 -- or -- measure from the front of the contact beam to the back of the wire and subtract the wire diameter divided by 2. If it is not, proceed as follows: For the manual handle assembly, refer to Section 4, WIRE INSERTION DEPTH ADJUSTMENT. For the pneumatic handle assembly, if the wire is inserted too deeply (more than the required wire insertion depth), refer to Section 4, WIRE INSERTION DEPTH ADJUSTMENT. If the wire is not inserted deeply enough (less than the required wire insertion depth), increase the air pressure by 69 kPa [10 psi]. Repeat the termination procedure and check the insertion depth. Continue in this manner until either the proper insertion depth is obtained or the air pressure is set to 483 kPa [70 psi]. If the proper insertion depth is NOT reached at 483 kPa [70 psi], return the air pressure to 276 kPa [40 psi], and refer to Section 4. 6. Inspect the termination according to Paragraph 3.2. 3.2. Termination Inspection (Refer to Figure 3) Refer to 114--1020 for detailed explanation of the termination inspection requirements. 1 — The required wire insertion depth is within the dimension given in Figure 3 (refer to Step 5 of Paragraph 3.1 for measurement). 2 — The end of the wire extends past the contact beam by at least 1.52 mm [.060 in.]. Figure 3 Contact (Partially Removed) 1.52 mm [.060 in.] Min End of Wire Extends Past Contact Beam Wire Retainer (Strain Relief) Removed Lock (Ramp, Ref) Test Connector Production Connector Wire Extends Past Wire Retainer (Strain Relief) Contact Beams Not Deformed Termination Inspection Wire Insulation Not Nicked or Cut 1 2 3 4 5 Wire 2.41+0.46/--0.13 mm [.095+.018/--.005 in.] Wire Insertion Depth (Front of Contact Beam to Center of Wire) CAUTION ! NOTE i NOTE i |
同様の部品番号 - 3--21028-2 |
|
同様の説明 - 3--21028-2 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |