データシートサーチシステム |
|
TL598 データシート(PDF) 5 Page - Texas Instruments |
|
|
TL598 データシート(HTML) 5 Page - Texas Instruments |
5 / 17 page TL598 PULSEWIDTHMODULATION CONTROL CIRCUITS SLVS053D − FEBRUARY 1988 − REVISED NOVEMBER 2003 5 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 electrical characteristics over recommended operating free-air temperature range, VCC =15V (unless otherwise noted) (continued) dead-time control section (see Figure 1) (see Note 4) PARAMETER TEST CONDITIONS MIN TYP† MAX UNIT Input bias current (DTC) VI = 0 to 5.25 V −2 −10 µA Maximum duty cycle, each output DTC = 0 V 0.45 Input threshold voltage (DTC) Zero duty cycle 3 3.3 V Input threshold voltage (DTC) Maximum duty cycle 0 V † All typical values, except for parameter changes with temperature, are at TA = 25°C. NOTE 4. Pulse-testing techniques must be used that maintain the junction temperature as close to the ambient temperature as possible. pwm comparator section (see Note 4) PARAMETER TEST CONDITIONS MIN TYP† MAX UNIT Input threshold voltage (FEEDBACK) DTC = 0 V 3.75 4.5 V Input sink current (FEEDBACK) V(FEEDBACK) = 0.5 V 0.3 0.7 mA † All typical values, except for parameter changes with temperature, are at TA = 25°C. NOTE Pulse-testing techniques must be used that maintain the junction temperature as close to the ambient temperature as possible. total device (see Figure 1) (see Note 4) PARAMETER TEST CONDITIONS MIN TYP† MAX UNIT Standby supply current RT = Vref, All other inputs and outputs open VCC = 15 V 15 21 mA Standby supply current RT = Vref, All other inputs and outputs open VCC = 40 V 20 26 mA Average supply current DTC = 2 V 15 mA † All typical values, except for parameter changes with temperature, are at TA = 25°C. NOTE 4. Pulse-testing techniques must be used that maintain the junction temperature as close to the ambient temperature as possible. switching characteristics, TA = 25°C (see Note 4) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT Output-voltage rise time CL = 1500 pF, VC = 15 V, VCC = 15 V, See Figure 2 60 150 ns Output-voltage fall time CL = 1500 pF, VC = 15 V, VCC = 15 V, See Figure 2 35 75 ns NOTE 4. Pulse-testing techniques must be used that maintain the junction temperature as close to the ambient temperature as possible. |
同様の部品番号 - TL598 |
|
同様の説明 - TL598 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |