データシートサーチシステム |
|
ADuM4150ARIZ-RL データシート(PDF) 11 Page - Analog Devices |
|
ADuM4150ARIZ-RL データシート(HTML) 11 Page - Analog Devices |
11 / 21 page Data Sheet ADuM4150 PACKAGE CHARACTERISTICS Table 10. Parameter Symbol Min Typ Max Unit Test Conditions/Comments Resistance (Input to Output)1 RI-O 1012 Ω Capacitance (Input to Output)1 CI-O 1.0 pF f = 1 MHz Input Capacitance2 CI 4.0 pF IC Junction-to-Ambient Thermal Resistance θJA 46 °C/W Thermocouple located at center of package underside 1 The device is considered a 2-terminal device: Pin 1 through Pin 10 are shorted together, and Pin 11 through Pin 20 are shorted together. 2 Input capacitance is from any input data pin to ground. REGULATORY INFORMATION The ADuM4150 is approved by the organizations listed in Table 11. See Table 16 and the Insulation Lifetime section for recommended maximum working voltages for specific cross-isolation waveforms and insulation levels. Table 11. UL CSA VDE Recognized Under UL 1577 Component Recognition Program1 Approved under CSA Component Acceptance Notice 5A Certified according to DIN V VDE V 0884-10 (VDE V 0884-10):2006-122 5000 V rms Single Protection Basic insulation per CSA 60950-1-07+A1+A2 and IEC 60950-12nd Ed+A1+A2., 800 V rms (1131 V peak) maximum working voltage3 Reinforced insulation, 849 V peak Reinforced Insulation per CSA 60950-1- 07+A1+A2 and IEC 60950-1 2nd Ed.+A1+A2, 400 V rms (565 V peak) maximum working voltage Reinforced insulation (2MOPP) per IEC 60601-1 Ed.3.1, 250 V rms (353 V peak) maximum working File E214100 File 205078 File 2471900-4880-0001 1 In accordance with UL 1577, each model is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 µA). 2 In accordance with DIN V VDE V 0884-10, each model is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 second (partial discharge detection limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10 approval. 3 Use at working voltages above 400 VAC RMS shortens lifetime of the isolator significantly. See Table 16 for recommended maximum working voltages under ac and dc conditions. INSULATION AND SAFETY RELATED SPECIFICATIONS Table 12. Parameter Symbol Value Unit Conditions Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration Minimum External Air Gap (Clearance) L(I01) 8.3 mm min Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L(I02) 8.3 mm min Measured from input terminals to output terminals, shortest distance path along body Minimum Internal Gap (Internal Clearance) 0.017 mm min Insulation distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1 Material Group II Material Group (DIN VDE 0110, 1/89, Table 1) Rev. A | Page 11 of 21 |
同様の部品番号 - ADuM4150ARIZ-RL |
|
同様の説明 - ADuM4150ARIZ-RL |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |